14.0 Release 1 (v14.0.7214)

14.0 Release 1 (v14.0.7214)

Released On

June 25, 2015

Release Type

Production Release

Release Location

Connexion.14.0.7214.exe
14.0 Release 1 (v14.0.7214)

Notes

Breaking Changes

Please see the breaking changes list here: Connexion.Core Interface Changes.

User device logging is now located in a file called Connexion.User.txt. There are 2 reasons for this change; first, we have seen PHI creep into the regular log file; second, on some systems we have had difficultly troubleshooting issues with Connexion because of the number of log messages generated by user devices.

New Features in this Release

Resolved

Description

Resolved

Description

CNXN-2356

Add extensibility points to CCD and HL7 transform V2 to allow these to be used as base devices

CNXN-2347

Create an SQL Inbound Device. (see the Database.Polling.Device.Sample on nuget for an example of how to setup this device)

CNXN-2345

Queue Device - It would be nice to have an option to preempt the Empty Queue Sleep time if a message is received

CNXN-2339

Logging - Should be a mechanism for logging Audit specific messages to a separate log file

CNXN-2338

EventHistory - Log messages from Custom Devices should go into their only log file in case they contain PHI

CNXN-2333

The client should detect an unclean shut-down and startup in "recovery mode"

CNXN-2290

Create interface-based transparent proxy from device UI to server-side device

CNXN-2138

As M*Modal Operations, I want to install and configure Hub more easily (Integrator)

 

Bug Fixes in this Release

Resolved

Description

Resolved

Description

CNXN-2366

Connexion Logger - Channel name in log printout does not update when Channel/Device name changes

CNXN-2365

ChangeHistoryDevice - Errors 5008 and 5148 due to repeated call to SetNextBackupTime

CNXN-2362

Queue Device Custom Search should honor manually entered/updated dates upon clicking Query

CNXN-2361

Channel names with special characters lost during backup/restore or cloning

CNXN-2360

Connexion not initiating FTPS connection

CNXN-2359

Incorrect description for RTrim(expression, string) in HL7 Transform Device

CNXN-2358

Remove() and Replace() are Case Sensitive

CNXN-2357

Save tracking setting (from the install wizard) not honored in the client

CNXN-2355

Incorrect description for Split(expression, charArray, index) in HL7 Transform Device

CNXN-2354

Incorrect description for SubString(expression, offset, length) in HL7 Transform Device

CNXN-2353

Right(expression, string/int) in HL7 Transform Device searches from left to right in the string

CNXN-2352

Selecting MatchPath(path, value) in drop down list in HL7 Transform Device populates "UnEscape(" instead

CNXN-2351

Incorrect description for LTrim(expression, string) in HL7 Transform Device

CNXN-2350

Incorrect description for LTrim(expression)

CNXN-2349

Incorrect description for In(expression, string1, string2,….,stringN) in HL7 Transform Device

CNXN-2348

HL7 Outbound Device donesn't adher to timeout setting

CNXN-2344

Disabled application servers should not generate "Server down" error messages

CNXN-2343

HL7 Transform Device v1 - IndexOf is Returning the Zero based Index

CNXN-2342

HL7 Transform Device v1 - Coalesce Expression Example should state "Returns the first NON empty value from the list of expressions"

CNXN-2341

Setting Max Message Size in HL7 Inbound Device has no effect

CNXN-2340

Ack Transformation in HL7 Inbound Device throws NullReferenceException

CNXN-2337

Installwizard fails when creating database(s) under certain conditions

CNXN-2336

HL7 Branch Help Page has been deleted and should be restored

CNXN-2334

Client Exception - @App:System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation.
---> System.NullReferenceException: Object reference not set to an instance of an object.

CNXN-2332

Stackoverflow in the textviewer when multiple collapsed regions are encountered

CNXN-2331

Inter app-server communications bindings mismatch

CNXN-2330

Enterprise - Connexion does not function properly with MS Cluster Services

CNXN-2329

Queue Device - It is possible to send data to a non-Queue device in Custom Code

CNXN-2328

Assembly Resolver - Should not cache the absence of an assembly

CNXN-2325

Custom Code Device - Compiler error: An assembly with the same identity has already been imported. Try removing one of the duplicate references.

CNXN-2323

Symbols requirement in the keyfile password dialog is overly restrictive (Integrator)

CNXN-2320

A user assigned to a group doesn't inherit the access of the group.

CNXN-2319

Queue Device - It should only be possible to Export messages to a Queue within the same group

CNXN-2318

It is possible to Bulk Export messages to a channel that doesn't have a Queue

CNXN-2317

Client Statistics - Stats information does not properly track the cursor